5.1.2.2: Assistive technology

Where ICT has closed functionality, that closed functionality shall be operable without requiring the user to attach, connect or install assistive technology and shall conform to the generic requirements of clauses 5.1.3 to 5.1.7 as applicable. Personal headsets and induction loops shall not be classed as assistive technology for the purpose of this clause.

Testing methods

Type of complianceTesting
Pre-conditions
  1. The ICT has closed functionality.
Procedure
    1. Determine the closed functions of the ICT.
    2. Check that the tests C.5.1.3 to C.5.1.6 can be carried out without the attachment or installation of any assistive technology except personal headsets or inductive loops.
      Result
      Pass: Check 2 is true
      Fail: Check 2 is false

      Requirement details

      Reference number: 5.1.2.2

      Related requirements

      Related functional statements

      Usage with limited cognition

      Related technical requirements

      No related technical requirements are associated with this technical requirement